Power grid areas¶
The power grid is divided (electrically) into areas in EFI-SNITT.DAT.
This file contains input for:
Header (counter)
Interconnections
End-point connection areas and busbars
Note |
|---|
It is important that the N interconnections in |
Header counter¶
Defines the number of interconnections in the file.
Record format:
<Number of interconnections>,
Example:
3,
Interconnections¶
Describes interconnections connecting two areas with corresponding busbars.
Interconnection header¶
Interconnection line counter and connecting areas.
Record format:
<Lines in interconnection>,<From area>,<To area>,
Fields:
1: Number of lines in the interconnection
2: From area
3: To area
Example:
The inteconnection consist of 2 lines between areas 2 and 3.
2, 2, 3,
Interconnection lines¶
Connection end-point busbars
Record format:
<Busbar from>,<Busbar to>,<description>,
Fields:
1: Busbar from
2: Busbar to
3: Description (optional)
Example:
The interconnection consist of 2 lines between areas 2 and 3 as defined in the interconnection header.
The lines N22 - N13 and N22 - N14 connects busbars 20022 - 30012 and 20022 - 30014. Where busbar 20022 is in area 2 and busbars 30013 and 30014 are in area 3.
20022,30013,N22 - N13,
20022,30014,N22 - N14,
Example complete file¶
C, -- Definisjon av snitt mellom delomr�der --
C, -- Totalt antall snitt: 3 --
3,
1, 1, 2,
10007,20008,N7 - N8,
2, 2, 3,
20022,30013,N22 - N13,
20022,30014,N22 - N14,
1, 1, 3,
10021,30023,N21 - N23,
C,
FILNAVN=,
C,